APC Pure Logo webp
shopping_cart 0 search menu

HI-2600 pH EC and DO Benchtop Meter

HI-2600 pH EC and DO Benchtop Meter Group Picture
Excl. VAT Incl. VAT
Code: HI-2600-02
Revert
  Pack Size List Price Qty  
photo_camera 1 Pack
HI-2600-02
£495.00
Revert
Pack: 1 Pack

£495.00

HI-2600 benchtop meter enables fast, accurate measurements utilising the Hanna Instruments digital electrode / probes for pH (HI-11310), ORP (HI-36180), conductivity (HI-763100), or dissolved oxygen (HI-764080). Each digital electrode / probe has a unique serial number and the parameter that it measures is automatically identified by the meter.

Once connected, the single sensor or sensors are ready to measure the parameter along with temperature.

The intuitive design simplifies configuration, calibration, measurement, data logging and transfer of data to a USB thumb drive or computer. The benchtop meter offers a Basic Mode that streamlines measurement configuration and is useful for routine applications.

The compact meter (and probe) can be used as a portable device (using its rechargeable battery) or used as laboratory instrumentation.

The meter has a large display with capacitive keys which features a 5.5” (14 cm) LCD. The large display provides a 130 ° wide viewing angle.

Key Features:

  • Automatic parameter recognition
  • pH/ORP choice of measurement units: pH, mV;
  • EC choice of measurement unit: Conductivity: µS/cm, mS/cm
  • TDS - ppm (mg/L), g/L
  • Salinity - NaCl, PSU, g/L
  • DO choice of measurement unit: ppm (mg/L), %
  • Adjustable resolution for pH and EC measurements
  • CAL Check indicators - HI-11310, HI-763100, HI-764080 digital probes only
  • Sensor Check indicators - HI-11311 and HI-12301 digital probes only
  • Basic mode for simplified operation
  • Dedicated GLP key
  • GLP data included with logged data
  • Simplified data transfer to a PC
  • Up to 8 hour battery life when used as a portable device
  • Internal clock and date

Digital probe input - simply connect each probe via the 3.5 mm jack, Digital Smart Electrodes are automatically recognised.

Clear, full text readout - The HI-2600 presents clear, detailed text prompts at the bottom section of the screen.

Two operating modes - HI-2600 can be used in Standard or Basic Operating Modes (pH and EC only). Standard Mode enables all features while Basic Mode displays a simplified screen and features —ideal for routine measurements.

Data logging - The HI-2600 provides ample data storage capacity, allowing you to save up to 1000 log records. Each data set comprehensively includes readings, GLP information, as well as date and time stamps.

GLP - The sensor retains data from the most recent calibration, including date, time, and buffers utilised. When connected to the HI-2600, this GLP information is automatically transferred.

CAL Check - Hanna’s exclusive CAL Check feature analyses the pH electrode’s response in calibration buffers to detect potential issues such as contaminated solutions or dirty electrodes. Upon completing calibration, indicators reflecting the probe’s condition—based on its offset and slope characteristics—are displayed on the measurement screen.

Sensor Check (using HI-11311 and HI-12301 pH probes only) - When paired with compatible Hanna electrodes featuring a matching pin, HI-2600 continuously monitors the impedance of the pH measuring electrode, providing real-time alerts in case of glass breakage. During calibration, Sensor Check displays the junction condition, by evaluating the reference junction resistance.

ORP measurement - Measure ORP (REDOX) in mV units by using a compatible ORP sensor.

Capacitive touch keypad - HI-2600 features sensitive capacitive touch buttons for accurate keystrokes for navigating menus and screens. Since they are part of the screen, the buttons can never get clogged with sample residue.

Easy to read LCD - HI-2600 features a 5.5” (14 cm) LCD display that you can clearly view from over 5 m (16.4’). The large display, with its wide 130° viewing angle, provides one of the easiest to read LCDs in the industry.

Rechargeable battery - The integrated rechargeable battery offers maximum portability with a long 8-hour battery life.

USB-C port for charging and data transfer - The HI-2600 features a streamlined USB-C port that facilitates charging the integrated rechargeable battery, transferring data to your computer, and exporting files directly to a flash drive.

Meter is supplied complete with:

  • HI-11310 pH digital electrode
  • HI-764026 Electrode holder with the following accessories: base plate with integrated pivot pin; cable holder clip, attached
  • pH calibration kit: pH 4 buffer solution (2 sachets); pH 7 buffer solution (4 sachets); pH 10 buffer solution sachets (2 sachets)
  • Electrode cleaning solution (2 sachets)
  • HI-920018 - 1.5m USB-C to USB-C cable
  • USB-C power adapter
  • Instrument quality certificate
  • Probe / electrode quality certificate
  • Battery safety insert
  • Quick reference guide with QR code for instruction manual download

Warranty - Meter has 2 years. 6 months from date of purchase for electrodes and probes

pH - using HI-11310 pH electrode  
   pH Range basic mode: -2.00 to 16.00 pH; standard mode: -2.000 to 16.000 pH
 Resolution basic mode: 0.01 pH; standard mode: 0.001 pH
 Accuracy (@25°C) basic mode: ±0.01 pH; standard mode: ±0.002 pH
 Calibration Basic Mode: Automatic, up to three points, option to select 5 standard buffers.
Standard mode: Automatic, up to five point calibration, 7 standard buffers available and two custom buffers.
   Temperature Compensation Automatic, -5.0 to 100.0°C (using integral temperature sensor)
 Logging Up to 1000* (in Standard Mode) records organised in:
• Manual log-on demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging in Standard Mode
mV - using HI-11310 pH electrode  
   mV pH Range ±1000 mV
 Resolution 0.1 mV
 Accuracy (@25°C) ±0.2 mV
ORP – using HI-36180 ORP electrode  
   ORP Range ±2000.0 mV
 Resolution 0.1 mV
 Accuracy (@25°C) ±0.2 mV (±999.9mV); ±1mV (±2000mV)
   Temperature Compensation Automatic, using integral temperature sensor -5.0 to 100.0°C
   Logging Up to 1000* (in Standard Mode) records organised in:
• Manual log-on demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging in Standard Mode
EC - using HI-763100 four-ring conductivity probe  
   EC Range 0.00 to 29.99 µS/cm;
30.0 to 299.9 µS/cm;
300 to 2999 µS/cm;
3.00 to 29.99 mS/cm;
30.0 to 200.0 mS/cm;
up to 500.0 mS/cm,
and absolute conductivity (TDS) is the conductivity value without temperature compensation
 Resolution 0.01 µS/cm;
0.1 µS/cm;
1 µS/cm;
0.01 mS/cm;
0.1 mS/cm
 Accuracy (@25°C) ±1% of reading (±0.5 µS/cm or 1 digit, whichever is greater)
 Calibration Cell factor calibration; six standards available: 84µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 118.8 mS/cm, one point offset: 0.00 µS/cm
   Temperature Compensation Automatic, -5 to 100.0°C; NoTC, can be selected to measure absolute conductivity
 Temperature Coefficient 0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C
Logging Up to 1000* (400) records organised in:
• Manual log-on demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging in Standard Mode, maximum 600 logs (100 lots)
TDS - using HI-763100 four-ring conductivity probe  
   TDS Range 0.00 to 14.99 mg/L (ppm);
15.0 to 149.9 mg/L (ppm);
150 to 1499 mg/L (ppm);
1.50 to 14.99 g/L;
15.0 to 100.0 g/L;
up to 400.0 g/L absolute TDS using 0.80 conversion factor
 Resolution 0.01 mg/L (ppm);
0.1 mg/L (ppm);
1 (ppm);
0.01 g/L;
0.1 g/L
 Accuracy (@25°C) ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
 Calibration through EC calibration
 TDS Factor in Standard Mode 0.40 to 0.80 (default value is 0.50)
Salinity - using HI-763100 four-ring conductivity probe  
   Salinity Range 0.0 to 400.0 % NaCl; 2.00 to 42.00 PSU; 0.00 to 80.00 g/L
 Resolution 0.1 % NaCl; 0.01 PSU; 0.01 g/L
 Accuracy (@25°C) ±1% of reading
 Calibration % NaCl only one point with HI-7037 standard
Dissolved Oxygen - using HI-764080 DO Probe  
   DO Range 0.00 to 45.00 PPM (mg/L); 0.0 to 300.0% saturation
 Resolution 0.01 ppm (mg/L); 0.1% saturation
 Accuracy ±1.5% of reading (± 1 digit)
 Calibration one or two point at 0% (HI-7040L solution) and 100% (water-saturated air)
 Pressure Compensation Automatic 450.0 to 850.0 mmHg – (0.1 mmHg resolution)
 Salinity Compensation 0 to 40 g/L – (1g/L resolution)
  Temperature Compensation 0.0 to 50.0°C)
   Logging Up to 1000 records organised in:
• Manual log-on-demand, maximum 200 logs
• Manual log-on-stability, maximum 200 logs
• Interval logging in Standard Mode, maximum 600 logs (100 lots)
Temperature  
   Temperature Range -20.0 to 120.0 °C
 Resolution 0.1°C
 Accuracy ±0.5°C
Additional Specifications  
PC Interface USB-C
Storage Interface USB-C
Power supply USB Type C (5 VDC; 500mA)
Environment 0 to 50˚C; Maximum 95% RH non-condensing
Dimensions 205 x 160 x 77 mm
Weight Approximately 0.85 kg
Ordering Information HI-2600 pH/EC/DO benchtop meter includes HI-11310 glass body refillable pH electrode, pH 4 buffer solution sachets (2), pH 7 buffer solution sachets (4), pH 10 buffer solution sachets (2), electrode cleaning solution sachets (2), electrode holder, 1.5 m USB-C to C USB-C cable. All HI-2600 series compatible pH, EC and DO digital probes are interchangeable with HI-2600 and can be ordered separately.

You may also like...

Cleaning solution pH probes, Hanna

Conductivity standard solution 1413uS/cm Hanna

GL890 Blue Nitrile Gloves, Powder Free, XS-XXL